Azure West US: maintenance automation withdrew routes from every WAN-egress device at once
A break-fix repair on one optical network device was expanded by a defective blast-radius analysis system to include all devices carrying egress from a West US datacenter. Routes were withdrawn from all of them simultaneously, severing the datacenter from Microsoft's WAN for about 5 hours; traffic inside the region was unaffected. Automated recovery could not run because connectivity was gone, so rollback was manual.
A reconstruction, not the operator's network. Hammerhead's authors rebuilt the change from the public record as a small network of their own. No configuration here is the operator's. What follows is what the tool reported on that reconstruction; it is not a claim that the tool would have prevented the outage.
What happened
Who: Microsoft Azure (tracking ID ZJV6-SGG)
The summary at the top is paraphrased from the sources below. Hammerhead's catalog rates its confidence in this account high.
Sources
What the public record says
- A break-fix repair on one optical network device was expanded by a defective blast-radius analysis system to include all devices carrying egress from a West US datacenter. Routes were withdrawn from all of them simultaneously, severing the datacenter from Microsoft's WAN for about 5 hours; traffic inside the region was unaffected. Automated recovery could not run because connectivity was gone, so rollback was manual.
- Who: Microsoft Azure (tracking ID ZJV6-SGG)
What the reconstruction assumed
Decided by Hammerhead's authors to build a network that runs. None of it describes the operator's network.
Everything below is ours.
- This incident rests on one or two write-ups (see the catalog's note on 2025 and 2026 dates).
- Draining is modelled as an outbound deny-all prefix-list on the egress device. Three egress devices; the repair as intended drains one, the push drains all three.
- Both runs carry --allow-flow-changes, the waiver an operator doing a planned drain passes, so that the intended change passes and the verdict on the push is not the generic tripwire.
- Cisco IOS syntax and stand-in address space throughout. A reconstruction, not any operator's configuration.
What Hammerhead said
Each run below is pinned by Hammerhead's replay tests at commit 0ee9732: the verdict and the quoted text are checked against the tool's output, and a run that disagrees fails the test. Reason lines are copied verbatim; a pinned line can be part of a longer reason. Every preflight run uses --max-blast-radius 100, so a change is never counted as caught merely because it touched many devices of a small network.
Hammerhead's own first-versus-now record
- First verdict
- pass for the intended drain, fail for the push (the datacenter subnet is lost from the WAN).
- Verdict now
- unchanged. The intended drain is also the control for the new idle-router check: the other two egress devices are ECMP members today, not idle.
Quoted from docs/replays/families/individual.md. “First” is the tool before the fixes this replay prompted.
the repair as intended: one egress device drained
now: passOn the reconstruction, hammerhead preflight on a before and an after snapshot with --allow-flow-changes returned pass.
Pinned in tests/gauntlet/replays-individual.yaml.
what the automation pushed: every egress device drained
now: failOn the reconstruction, hammerhead preflight on a before and an after snapshot with --allow-flow-changes returned fail, for the reasons below.
Reason text pinned (some reason contains each line)
- connected subnet(s) reachable before are not reachable after
- 198.18.0.0/24 on DC-FABRIC-1
Pinned in tests/gauntlet/replays-individual.yaml.
Limits
- The configurations are a reconstruction. Where the record is silent, the assumptions above fill the gap; if one is wrong, the replay is wrong in that respect.
- A verdict describes the reconstructed network's converged state. Timing, traffic load, and anything a device does that no configuration states, such as software reacting to a health check or a firmware bug, are outside it.
- A pass is reported as a pass. A fail says a gate fired on the reconstruction, nothing more.
- Why the catalog counts this outage as in scope: Evaluating the aggregate candidate (all egress devices drained together) instead of each device alone shows the datacenter loses every path to the WAN; this is exactly a lost-redundancy / reachability-regression gate.
Imported from docs/replays/azure-westus-2026/FACTS.md and the replay manifests in the Hammerhead repository at commit 0ee9732.